What's in the box
- 1 × MRCOOL® 35 ft R-454B No-Vac Quick Connect Line Set
- Professional installation is recommended.
- This No-Vac Quick Connect line set is designed for compatible MRCOOL® R-454B systems and should be installed according to the product installation documentation.
- Always confirm compatibility with your specific system model before installation.
- Free standard shipping is available on eligible orders to the Lower 48 states and Washington, D.C.
- Orders are generally processed within 3–5 business days, followed by approximately 5–12 business days in transit.
- Smaller items may ship by parcel carrier. Larger equipment may be delivered curbside by freight carrier, and the carrier may contact you to coordinate delivery.
- Return requests may be submitted within 30 calendar days of delivery. Products must be new, unused, uninstalled, complete and in their original manufacturer packaging. Powered products must not have been energized.
- For approved change-of-mind, incorrect-sizing or customer-ordering-error returns, the customer is responsible for return freight and a 15% restocking fee. Verified damaged, defective, incorrect or incomplete orders are handled separately.
View our Shipping Policy and Returns & Warranty Policy.
Manuals & documents
MODEL: NV35-3834-O
Quick Connect Line Set for Compatible MRCOOL® Systems.
Need extra line set length for your compatible MRCOOL® VersaPro or Central Ducted Hyper Heat system?
The MRCOOL® 35 ft R-454B No-Vac Quick Connect Line Set is designed to help simplify installation by providing a precharged, kink-resistant line set with secure Quick Connect fittings.
Built for compatible R-454B systems, this 35 ft line set includes UV-protected insulation to help protect performance and durability during installation.
The No-Vac design helps reduce installation complexity by eliminating the need for traditional vacuuming when used with compatible MRCOOL® equipment.
With 3/8" liquid and 3/4" suction line sizing, this accessory is made for specific MRCOOL® central ducted applications and should be matched carefully before purchase.
Simple connection. Longer reach. Built for compatible MRCOOL® systems.
Why You’ll Love It
✅ 35 ft No-Vac line set
✅ Designed for compatible R-454B systems
✅ Precharged for simplified installation
✅ Simple secure Quick Connect fittings
✅ Kink-resistant design
✅ UV-protected insulation
✅ Longer reach for flexible installation layouts
✅ Designed for compatible MRCOOL® VersaPro and Central Ducted Hyper Heat systems
Best For
MRCOOL® VersaPro Systems • Central Ducted Hyper Heat Systems • Compatible R-454B Installations • Longer Line Set Runs • Replacement Line Sets • Professional HVAC Installations
Compatibility
- Works with compatible MRCOOL® VersaPro 2nd Gen and Central Ducted Hyper Heat 2nd Gen systems.
- Always confirm system compatibility, refrigerant type, line size, and required line set length before purchase.
| Product Type | Line Set |
| Model | NV35-3834-O |
| Length | 35 ft |
| Refrigerant | R-454B |
| Factory Charge | 5.73 oz |
| Connection Type | Quick Connect |
| Liquid Line | 3/8" |
| Suction Line | 3/4" |
| Insulation | UV Protected |
| Design | Kink Resistant |
| Chemical Disclosure | Contains Chemicals |
| Net Weight | 32 lb |
| Box Dimensions | 41" W × 41" H × 5" D |
| Gross Weight | 37 lb |
Questions, answered
Everything homeowners ask before buying a MRCOOL® system.
Installation
What installation requirements apply to this product?
Installation requirements vary by product type. Selected complete MRCOOL® DIY systems are designed for homeowner installation when fitted in line with the manufacturer’s instructions, local codes and permit requirements.
Central HVAC systems, including Universal®, VersaPro®, Central Ducted Hyper Heat and packaged systems, are intended for professional installation by a qualified HVAC contractor. Licensed electrical work may also be required.
Components, thermostats, controls, line sets and accessories should be installed according to their product documentation and compatibility requirements. Always review the product page, manufacturer guidance and warranty conditions before installation.
Will I need any additional parts, tools or professional services?
Additional requirements vary by product and installation. Tools, electrical materials, mounting hardware, connecting components or other installation supplies may be required unless specifically stated as included.
Review the product description, specifications, installation information and What’s Included section, where available, before ordering.
Where can I find product documents or installation instructions?
Available specifications, installation instructions, owner’s manuals and manufacturer documents are provided on the product page where applicable.
Some simple accessories may not have a separate installation manual. Contact our team if you need help locating documentation for a particular product or model.
Sizing & Compatibility
How do I confirm this product is compatible with my equipment?
Review the product type, model number, dimensions, voltage, capacity, refrigerant type, connection sizes and compatibility information shown on the product page, where applicable.
Components, thermostats, controls and accessories must be matched to compatible equipment. Contact our team before ordering if you are uncertain about compatibility.
What should I check before ordering?
Confirm the product name and model number, together with any relevant dimensions, voltage, capacity, refrigerant type, connections and installation requirements.
For replacement components and accessories, compare the product specifications with your existing equipment and the relevant manufacturer documentation before placing your order.
What is included with this product?
The supplied items are listed in the What’s Included section or product description, where applicable. Only the products, components and accessories specifically stated are included.
Electrical materials, mounting equipment, connecting components or other installation supplies may need to be purchased separately unless expressly stated otherwise.
Warranty & Support
What warranty coverage applies to this product?
Warranty coverage varies by product and model. Eligible MRCOOL® products are covered according to the manufacturer’s warranty terms, registration requirements and installation conditions.
Accessories and individual components may have different coverage. Cool Heat Direct can provide available warranty documentation and general guidance, while warranty eligibility and claim decisions are determined by the manufacturer.
How can I get help before ordering?
Email support@coolheatdirect.com with the product name or model number and details about your project or existing equipment.
For compatibility questions, include the model numbers of any products you intend to connect, control, replace or use together.
Support hours: Monday–Friday, 9 AM–6 PM ET.
Shipping & Returns
How will my order be shipped?
Free standard shipping is available on eligible orders to the Lower 48 states and Washington, D.C.
Orders are generally processed within 3–5 business days, followed by approximately 5–12 business days in transit. Delivery timing varies by product availability, destination and carrier scheduling.
Smaller products may ship by parcel carrier. Larger equipment may be delivered curbside by freight carrier. The carrier may contact you to arrange a delivery appointment.
Can I return this product?
Return requests may be submitted within 30 calendar days of delivery. Products must be new, unused and uninstalled and, where applicable, unpowered. They must also be complete and in their original manufacturer packaging. Prior written authorization is required.
For approved change-of-mind returns, incorrect sizing or customer ordering errors, the customer is responsible for return freight and a 15% restocking fee applies.
Verified damaged, defective, incorrect or incomplete orders are handled separately under our full policy.

